Balady Platform - MoMRAH Updated Collective Housing Standards 1446 AH

Balady Collective Housing Licensing & Inspection Portal

Comprehensive digital platform for statutory worker housing capacity calculations, automated civil defense & health compliance auditing, and instant issuance of certified municipal permits.

4.0 sqm / workerMinimum net bedroom area
1 toilet / 5 workersMandatory sanitary fixture ratio
Civil DefenseLive safety standards verification
Balady Digital SealEncrypted QR verification
Licensed Facilities
8,420+

Municipally certified compounds

Licensed Capacity
680K+

Workers in compliant housing

Average Audit Speed
48h

Instant electronic certificate

National Compliance Rate
93.4%

Fully compliant facilities

Quick Calculation Presets:

Capacity & Municipal Standards Calculator

Enter property specifications and amenities to compute legal worker capacity compliant with MoMRAH regulations

Areas & Dimensions

sqm

sqm

Minimum 4.0 sqm per worker

Rooms & Sanitary Fixtures

Minimum 1 fixture per 5 workers

Mandatory Facilities & Services
Civil Defense & Fire Safety
Real-time Compliance Audit ScoreboardMunicipally Certified
300workers maximum

Calculated by the limiting factor between net bedroom space and sanitary fixtures

Limiting Factor: Optimal & Balanced Allocation of Space & Facilities
Capacity by Area: 300Capacity by Toilets: 300
Allocated Space Per Worker
4 م² Compliant
Statutory minimum standard: 4.0 sqm per worker
Workers Per Sanitary Fixture
5 workers / toiletCompliant
Statutory maximum ratio: 5.0 workers per fixture
Class A (Excellent Compliance - 3 Years)Full satisfaction of mandatory standards plus advanced amenities
Class A100%
Facility is legally eligible for a 3-year collective housing license
Estimated Annual Municipal FeesPer Municipal Tariff Schedule
Field Audit & Inspection Fee500 SAR
Annual Worker Housing Licensing Fee (300 × 20 SAR)6,000 SAR
Balady Platform Service Fee100 SAR
Value Added Tax (15%) (15%)990 SAR
Total Estimated Fees7,590 SAR

Self-Inspection & Audit Checklist (Health & Civil Defense)

MoMRAH self-audit guide to ensure complete facility readiness prior to official municipal inspection

Mandatory +10%

Stainless steel food prep surfaces, proper refrigeration, and mechanical exhaust ventilation

Mandatory +10%

Medical examination bed, emergency pharmaceutical supplies, and isolated quarantine room

Mandatory +8%

Valid contract with licensed pest control firm and up-to-date periodic inspection log

Mandatory +8%

Proper air conditioning across all dormitories and compliant fresh air exchange systems

Mandatory +15%

Official active Civil Defense safety license for the collective housing structure

Mandatory +10%

Central fire alarm panel with smoke/heat detectors in corridors, rooms, and audible sirens

Mandatory +10%

Automatic sprinkler network, fire hose reels, and inspected portable extinguishers

Mandatory +7%

Outward-opening panic hardware doors, backup emergency lighting, and clear egress corridors

Mandatory +8%

Comprehensive engineering safety certificate verifying structural integrity without hazardous defects

Mandatory +6%

Insulated distribution boards, surge protection, and ground fault circuit interrupters

Mandatory +4%

Heavy-duty commercial washing machines proportioned to capacity with hygienic drainage

Mandatory +4%

Multi-stage water filtration units, stainless chillers, and tested potable water quality

Mandatory +4%

Sealed bins preventing odor and vermin, with scheduled daily municipal collection

+4%

Security monitoring coverage for main entrances, common courtyards, and perimeter corridors